CollegeSource Accessibility Conformance Report
Based on Voluntary Product Accessibility Template® (VPAT®)1

VPAT Version 2.0 Beta 2


Name of Product: Transferology™ Lab 1.9

Date: November 25,  

Contact information: melissa@collegesource.com

Notes:

Standards/Guidelines

This report covers the degree of conformance for the following accessibility standard/guideline:

Standard/Guideline

Included In Report

Web Content Accessibility Guidelines 2.0, at http://www.w3.org/TR/2008/REC-WCAG20-20081211/

Level A = Y

Level AA  = Y

Level AAA = N

Section 508 as published in 2017, at http://www.Section508.gov

Y

EN 301 549 Accessibility requirements suitable for public procurement of ICT products and services in Europe, at http://mandate376.standards.eu/standard

N

Table Information

For each of the standards, the criteria are listed by chapter in a table. The structures of the tables are: the first column contains the criteria being evaluated, the second column describes the level of conformance of the product with regard to the criteria, and the third column contains any additional remarks and explanations regarding the product.

  • By default the table information is showing. This information can be hidden by clicking “Click to show or hide table data.” This allows users to hide information so they see only the sections they need.
  • When sections of criteria do not apply, or are deemed by the customer as not applicable, the section is noted as such and the rest of that table may be removed for that section.
  • When multiple standards are being recorded in this document, the duplicative sections are noted and responded to only one time. The duplicate entry will note the cross reference to the data.

Terms

The terms used in the Conformance Level information are defined as follows:

  • Supports: The functionality of the product has at least one method that meets the criteria without known defects or meets with equivalent facilitation.
  • Supports with Exceptions: Some functionality of the product does not meet the criteria.
  • Does Not Support: Majority of functionality of the product does not meet the criteria.
  • Not Applicable: The criteria are not relevant to the product.
  • Not Evaluated: The product has not been evaluated against the criteria (can be used only with WCAG 2.0 Level AAA)


WCAG 2.0 Report

Tables 1 and 2 also documents conformance with:

  • EN 301 549:  Chapter 9 - Web, Chapter 10 - Non-Web documents, Section 11.2.1- Non-Web Software (excluding closed functionality), and Section 11.2.2 - Non-Web Software (closed functionality).

Table 4 documents the WCAG conformance statements:

  • WCAG
  • EN 304 549: Chapter 9 - Web

Table 1: Conformance Criteria, Level A

Notes:

CriteriaConformance Level Remarks and Explanations

1.1.1 Non-text Content (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports

Software:

Software: WCAG 2.0 Level A; Required

  • Pop-up dialog for submitting audit - BUTTON elements must have text content
  • FAQ page - missing alt text
  • Request Information - Program input TEXT must be unique on page
  • Choose an Option page - missing alt text
  • Course Will Count for Full Credit; Notes About Transfer Rule - link text must describe the link target
  • Menu bar - text overlaps at 200%

View Transferology Lab Accessibility Roadmap for Status and Timeline

1.2.1 Audio-only and Video-only (Prerecorded) (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports

Software: No known issues

1.2.2 Captions (Prerecorded) (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports

Software: No known issues

1.2.3 Audio Description or Media Alternative (Prerecorded) (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports

Software: No known issues

1.3.1 Info and Relationships (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Home page - text in the Already Have TES or uAchieve? and Webinars messages have low contrast
  • Home page - Transferology Lab version and copyright have low contrast
  • Login button - text has low contrast
  • Login error message - text has low contrast
  • Request Lab Account - Back to Login and Send Request buttons - text has low contrast
  • Can't Sign In? page - Email input box is missing form label
  • Can't Sign In? page - Email input box and REQUEST PASSWORD RESET text have low contrast
  • Recovery Code, New Password, and Re-enter Password input boxes - missing form labels
  • General Information tab - Request Daily Limit - input box has broken ARIA
  • + Add button for the General Contact Emails - low contrast between the foreground and background colors
  • Trash can icon for deleting campuses - empty link
  • + Create Users button, Active button, and Inactive buttons - low contrast
  • Replacement Course - Zip Code field and Clear Filters button have broken ARIA
  • + Create Transfer Bundle and # of Courses buttons - low contrast
  • All pages in the Lab have Skip Navigation links, but the target links do not exist
  • Questions and Answers page - broken ARIA reference
  • Multiple buttons throughout the Audit page - low contrast
  • Recruiting Students - Name column has empty link
  • Need Advising page - Name column has empty link
  • + Create Category Mappings button - low contrast
  • Add Glossary Message button - low contrast
  • TES Evaluations page - Date Range input boxes (Start/End Date) have multiple form labels
  • Unknown Equivalencies - Prev < and Next > buttons for the Date Range are missing text in the table header
  • TES Evaluations page - drop-down values have low contrast
  • Unknown Equivalencies page - drop-down values have low contrast
  • TES Mode sidebar - Delete buttons (links) contain no text
  • + Create Program button - low contrast
  • + Create Question button - low contrast
  • Save Program button - empty form label
  • Answers page - Edit and Delete buttons - empty links
  • Course Catalog Import/Export - pop-up window drop-down has multiple form labels
  • Course Catalog Import/Export - pop-up window has table with no content
  • Export Course Catalog - file selection box is missing form label
  • View Student Statistics - Date Range - Prev < & Next > - empty table header
  • View Student - Lab Statistics - Date Range - all buttons in the open Calendar fail to meet the CCR (Color Contrast Ratio) threshold
  • Pathway Management - Filter field is missing form label
  • Year Term Conversion - + Create Year/Term Conversion button does not meet the CCR threshold
  • Input box for Student Referral link - missing form label
  • Delete School Partner buttons - contain no text
  • Pathway checkbox - empty form label
  • Username link color - does not meet the CCR threshold
  • Delete and Edit School Group columns - table header contains no TEXT
  • User group modal label - empty heading
  • Edit and Delete School Group buttons - empty links
  • Badge Group - users do not meet the CCR threshold
  • Users and Schools button colors - do not meet the CCR threshold
  • Tag buttons Schools and Users - color has low contrast color
  • Most Active Users filter - input box is missing form label
  • View Profile link - empty link
  • Logging page - document language is missing
  • Logging page - root logging level, Reload file, drop-down box, Set Root Level, and Enable Users specific logging - form labels missing
  • TES Evaluations - cannot use keyboard to select date from the drop-down menu
  • Using the keyboard to Add, Edit, Save, or Run the first program on the page - cursor jumps to the bottom of the page instead of staying in the same location
  • Using the keyboard to Add, Edit, or Save the first question on the page - cursor jumps to the bottom of the page and user focus is lost
  • Cannot use the keyboard to access the < Prev or Nex > button across the application where there is date range
  • Transfer Equivalencies - NVDA does not read the form label "Filter"
  • Transfer Equivalencies page - NVDA announces "clear filters" link 8 times
  • Course List - NVDA does not announce the actual word "hours," but only reads the number in the 4th column
  • Programs page - NVDA announces the word "clickable" 10 times for the word "Program"
  • Check Program - checkbox column has empty table header
  • Check Program - all checkboxes are missing form labels
  • Check Program/Submitted Audits - input box has empty form label
  • Check Programs/Request Audits - cannot use the keyboard to access the Help (?) image
  • Check Programs/Request Audits - NVDA does not read the Close (X) button
  • Check Programs - NVDA announces the word "clickable" 6 times for the Override Year Term input box
  • Check Programs/Request Audits - NVDA does not read the tooltips
  • Check Programs - focus is lost once the user selects the Run Audits button
  • Pathway Agreement - NVDA does not read the entire warning paragraph that appears in the pop-up window
  • Pathway Agreement - spacebar does not work when NVDA is activated; cannot use spacebar to select the checkbox
  • Pathway Management - cannot use keyboard to view the Hints message
  • Submitted Audits page - cannot use keyboard to view Program, Status, or Run Audit status
  • Switch School link - school admin cannot use the keyboard to view hidden message for either Tips or Help

View Transferology Lab Accessibility Roadmap for Status and Timeline

1.3.2 Meaningful Sequence (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Course List - NVDA does not read the word "Hours"
  • Programs page - NVDA announces the word "clickable" 10 times for the word "Program"
  • Check Programs/Request Audits - NVDA does not read the tooltips
  • Check Programs - NVDA announces the word "clickable" 6 times for the Override Year Term input box
  • Pathway Agreement - NVDA does not read the entire warning paragraph

View Transferology Lab Accessibility Roadmap for Status and Timeline

1.3.3 Sensory Characteristics  (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Course List - NVDA does not read the word "Hours"
  • Programs page - NVDA announces the word "clickable" 10 times for the word "Program"
  • Check Programs/Request Audits - NVDA does not read the tooltips
  • Check Programs - NVDA announces the word "clickable" 6 times for the Override Year Term input box

View Transferology Lab Accessibility Roadmap for Status and Timeline

1.4.1 Use of Color (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with exceptions

Software:

  • Home Page - text in the Already Have TES or uAchieve? and Webinars messages has low contrast
  • Home Page - Transferology lab version and copyright text have low contrast
  • Login button - text has low contrast
  • Login error message - text has low contrast
  • Request Lab Account - Back to Login and Send Request button text has low contrast
  • Can't Sign In? page - email input box and REQUEST PASSWORD RESET text has low contrast
  • + Add button for the General Contact Email - low contrast
  • + Create Users button, Active button, and Inactive button - all have low contrast between the foreground and background colors
  • + Create Transfer Bundle and # of Courses - low contrast
  • Multiple buttons throughout the Audit page - low contrast
  • + Create Category Mappings button - low contrast
  • Add Glossary Message button - low contrast
  • TES Evaluations page - drop-down values have low contrast
  • Unknown Equivalencies page - drop-down values have low contrast
  • + Create Program button - low contrast
  • + Create Question button - low contrast
  • View Student/Lab Statistics/Date Range buttons in the open Calendar - do not meet the CCR (Color Contrast Ratio) threshold
  • + Create Year/Term Conversion button - does not meet the CCR threshold
  • Username link color - does not meet the CCR threshold
  • Tag Schools and Users button colors - do not meet the CCR threshold
  • sendResults - button has low contrast
  • Blue path - "First" button for "Filter by school or City name" has low contrast
  • Blue path - Matches/Misses/Maybe/No Match - all tabs have low contrast
  • Blue path - "For credit at" header has low contrast
  • Add Bundle on green path - Search button has low contrast
  • matchResults page - My School has low contrast
  • Apply Courses to a Program - button has low contrast

View Transferology Lab Accessibility Roadmap for Status and Timeline

1.4.2 Audio Control (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports

Software: No known issues


2.1.1 Keyboard (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • TES Evaluations page - cannot use keyboard to select date from the drop-down menu
  • When using the keyboard to Add, Edit, Save, or Run the first program on the page, the cursor automatically jumps to the bottom of the page instead of staying in the same location so the user focus is no longer at the top of the page
  • Edit, Add, and Save the first question on the page - cursor moves to the bottom of the page
  • Check Programs - Request Audits - cannot use the keyboard to access the Help (?) image
  • Pathway Agreement - spacebar does not work when NVDA is activated; cannot use spacebar to select the checkbox
  • Pathway Management - cannot use keyboard to view the Hints message
  • Submitted Audits page - cannot use keyboard to view either Program, Status, or Run audit status
  • Switch School link - school admin cannot use the keyboard to view the hidden message for either Tips or Help

Keyboard inaccessible:

Transfer Equivalencies page:

      • Clear filters - tooltips
      • FB icon - tooltips
      • Print icon - tooltips

Replacement Course page:

      • Search icon - tooltips
      • Clear filters - tooltips
      • Email These Results - tooltips

Course Bundles page:

      • Share Course Bundle icon - Sent to you by...
      • + Add Course icon - can hover over using mouse to view the hidden text message, but not via keyboard
      • Trash Can icon - cannot view tooltips with keyboard

Search Results page:

      • Looking For a Particular School? - tooltips not accessible via keyboard
      • Favorite icon
      • View Full Profile
      • Checkbox - Favorites only

Match Result page:

      • Print icon
      • Matches tab - courses matches at this school
      • Maybe tab - unreviewed courses at this school
      • Misses tab - no matches at this school
      • School profile and Favorite icon
      • Web - below school address - tabbing to web link does not display the tooltips
      • Phone Number link
      • Apply Course to a Program link

School Info page:

      • Program Name link
      • Clear Filters link
      • See How Your Courses Might Apply to This Program

My Program Requests page:

      • Status
      • Processing - spinning wheel
      • Error - image
      • Error Occurred - image
      • Complete  - Checkmark symbol
      • Email - Envelope icon
      • Delete - Trash Can icon

Manage Source Schools page:

      • Unknown Schools
      • Search icon
      • Hide icon
      • Find School - Search icon
      • + Request as a New School
      • Linked Schools
      • Alert icon - School Code does not match record
      • Unlink icon

Glossary Messages page:

      • Edit and Delete icons
      • + Create Message button

Popular Courses page:

      • Export & Print icons

Unknown Equivalencies page:

      • Export and Print icons

Manage Programs page:

      • View File Format
      • Run Program icon
      • Edit Program icon
      • Delete icon

Program Questions page:

      • View File Format
      • Edit Answers icon
      • Edit Question icon
      • Delete Question icon

Answers page:

      • Edit and Delete icons

Pending Audit Requests page:

      • Run Again Now icon
      • Cancel icon

Profile Preview page:

      • Information Links - all tooltip icons
      • Toggle Edit mode

Campuses page:

      • Remove Child icon

Users page:

      • + Create User button
      • Student and Lab Statistics
      • Graph icons

Year Term Conversions page:

      • + Create Year Term Conversion button
      • Edit icon
      • Delete icon

Pathway Management page:

      • Total Pathways
      • View Pathway
      • Disabled Trash Can icon - this school can only be deleted once all pathways are removed

View Transferology Lab Accessibility Roadmap for Status and Timeline

2.1.2 No Keyboard Trap (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:


Software: No known issue

2.2.1 Timing Adjustable (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports


Software: No known issue


2.2.2 Pause, Stop, Hide (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:


Software: No Known Accessibility issues

2.3.1 Three Flashes or Below Threshold (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports


Software: No known issue


2.4.1 Bypass Blocks (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software) – Does not apply to non-web software
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs) – Does not apply to non-web docs

Software: Supports


Software: No known issue

2.4.2 Page Titled (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Can't Sign In? page - missing form label
  • View Student Statistics/Date Range - empty table header
  • Delete and Edit School Group columns - table header contains no text
  • Delete and Edit School Group columns - heading is empty
  • Courses From: heading level is invalid
  • Green path: sortOrder - has no explicit label
  • Green path: nameSearch - input field has visible form label
  • Add/Edit bundle - select Year box, missing form label
  • Blue path: sortOrder - has no label
  • Replacement Course - heading order is invalid
  • Transfer Equivalencies/filter - heading order is invalid

 View Transferology Lab Accessibility Roadmap for Status and Timeline

2.4.3 Focus Order (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Edit, Save, and Run the first program on the page - focus does not stay in order of sequence, but instead jumps to the bottom of the page
  • Edit, Add, and Save the first question on the page - focus does not stay in order of sequence, but instead moves to the bottom of the page
  • Check Programs - focus is lost once the user selects the Run Audits button

View Transferology Lab Accessibility Roadmap for Status and Timeline

2.4.4 Link Purpose (In Context) (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • All pages in the Lab have Skip Navigation links, but the target links do not exist
  • Recruiting Students - Name column has empty link
  • Input box for Student Referral link - missing form label
  • Username link - low contrast color
  • Most Active Users - View Profile link has empty link
  • Pathway Management - cannot use keyboard to view the Hints message
  • Submitted Audits page - cannot use keyboard to view Program, Status, or Run Audit status

View Transferology Lab Accessibility Roadmap for Status and Timeline

3.1.1 Language of Page (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Logging page - document language is missing


View Transferology Lab Accessibility Roadmap for Status and Timeline

3.2.1 On Focus (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:  

Supports with Exceptions

Software:

  • Check Programs - focus is lost once the user selects the Run Audits button


View Transferology Lab Accessibility Roadmap for Status and Timeline

3.2.2 On Input (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Can't Sign In? page - missing form label
  • Input boxes for Recovery Code, New Password, and Re-enter Password - missing form labels
  • General Information tab - Request Daily Limit - input box has broken ARIA
  • TES Evaluations page - input boxes for the Date Range have multiple form labels
  • Input box for Student Referral link - missing form label
  • Filter Most Active Users input box - missing form label
  • Check Program - Submitted Audits - input box has empty form label
  • Check Programs - Request Audits - NVDA announces "clickable" 6 times for the Override Year Term input box

View Transferology Lab Accessibility Roadmap for Status and Timeline

3.3.1 Error Identification (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Login error message - text has low contrast


View Transferology Lab Accessibility Roadmap for Status and Timeline

3.3.2 Labels or Instructions (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Can't Sign In? page - missing form label
  • Recovery Code, New Password, and Re-enter Password input boxes - no form labels
  • General Information tab - Request Daily Limit - input box has broken ARIA
  • TES Evaluations page - Date Range input boxes (Start/End Date) have multiple form labels
  • Course Catalog Import/Export - pop-up window has table with no content
  • Export Course Catalog - file selection box - missing form labels
  • View Student - Lab Statistics - Date Range - empty table header
  • Pathway Management - Filter field - missing form label
  • Input box for Student Referral Link - missing form label
  • Pathway checkbox - empty form label
  • Delete and Edit School Group columns - table header contains no text
  • Filter Most Active Users - input box - missing form label
  • Transfer Equivalencies - NVDA does not read the form label "Filter"
  • Check Program - checkbox column - empty table header
  • Check Program - Request Audits - Override Year Term field is missing form label

View Transferology Lab Accessibility Roadmap for Status and Timeline

4.1.1 Parsing (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

  • Edit Message/Input box
  • Glossary Messages/Types to show/checkbox
  • Mataches/Maybe/Miss/Taken
  • Pathways to and from my school
  • Share bundle
  • Shows Hints:
  • TES Evaluation page


View Transferology Lab Accessibility Roadmap for Status and Timeline

4.1.2 Name, Role, Value (Level A)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Export Course Catalog - File Name selection box - missing form labels
  • View Student Statistics/Date Range - empty table header
  • Input box for Student Referral Link - missing form label
  • Pathway checkbox - empty form label
  • Delete and Edit School Group columns - table header contains no text
  • Transfer Equivalencies - NVDA does not read the form label header "Filter"
  • Course List - NVDA does not announce the word "Hours"
  • Check Programs/Request Audits - NVDA does not read the tooltips


 View Transferology Lab Accessibility Roadmap for Status and Timeline

 

Table 2: Conformance Criteria, Level AA

Notes:

CriteriaConformance LevelRemarks and Explanations

1.2.4 Captions (Live) (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports

Software: No known issue

1.2.5 Audio Description (Prerecorded) (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports

Software: No known issue

1.4.3 Contrast (Minimum) (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Home Page - text in the Already Have TES or uAchieve? and Webinars messages - low contrast
  • Can't Sign In? page - email input box and REQUEST PASSWORD RESET text - low contrast
  • + Add button for the General Contact email - low contrast
  • + Create Users, Active, and Inactive buttons - low contrast between the foreground and background colors
  • + Create Transfer Bundle and # of Courses - low contrast colors
  • Multiple buttons throughout the Audit page- low contrast
  • + Create Category Mappings button - low contrast color
  • Add Glossary Message button - low contrast
  • Unknown Equivalencies page - drop-down values - low contrast
  • TES Evaluations page - drop-down values - low contrast
  • + Create Program button - low contrast
  • + Create Question button - low contrast
  • View Student - Lab Statistics - Date Range - all buttons in the open Calendar fail to meet the CCR (Color Contrast Ratio) threshold
  • + Create Year/Term Conversion button does not meet the CCR threshold
  • Username link color does not meet the CCR threshold
  • School Tag buttons and Users Tag buttons do not meet the CCR threshold


View Transferology Lab Accessibility Roadmap for Status and Timeline

1.4.4 Resize text (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports

Software: No known issue

1.4.5 Images of Text (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports

Software: No known issue

2.4.5 Multiple Ways (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software) – Does not apply to non-web software
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs) – Does not apply to non-web docs

Software: Supports

Software: No known issue

2.4.6 Headings and Labels (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Can't Sign In? page - email input box is missing form label
  • The following input boxes are missing form labels: Recovery Code, New Password, and Re-enter Password
  • General Information tab - Request Daily Limit - input box has broken ARIA
  • Trash Can icon to delete campuses - empty link
  • Replacement Course - Zip Code field and Clear Filters button have broken ARIA
  • TES Evaluations page - Date Range input boxes have multiple form labels
  • Course Catalog Import/Export - pop-up window has table with no content
  • Export Course Catalog - File Name selection box is missing form label
  • View Student Statistics/Date Range - empty table header
  • Pathway Management - Filter field is missing form label
  • Pathway checkbox - empty link
  • Delete and Edit School Group columns - table header contains no text
  • Filter Most Active Users - input box missing form label
  • Transfer Equivalencies - NVDA does not read the form label header "Filter"
  • Check Program - checkbox column has empty table header
  • Check Program/Request Audits - Override Year Term field - missing form label
  • Check Program - all checkboxes are missing form labels
  • Check Program/Submitted Audits - input box has empty form label

View Transferology Lab Accessibility Roadmap for Status and Timeline


2.4.7 Focus Visible (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Can't Sign In? page - error message and REQUEST PASSWORD RESET text has low contrast
  • Using keyboard to Add, Edit, Save, or Run the first program on the page moves the cursor to bottom of the page, losing user focus
  • Check Programs - focus not visible


View Transferology Lab Accessibility Roadmap for Status and Timeline


3.1.2 Language of Parts (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Supports with Exceptions

Software:

  • Logging page - document language missing


View Transferology Lab Accessibility Roadmap for Status and Timeline


3.2.3 Consistent Navigation (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software) – Does not apply to non-web software
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs) – Does not apply to non-web docs

Software:

Supports with Exceptions

Software:

  • Skip Navigation links - broken on every page in the Lab

View Transferology Lab Accessibility Roadmap for Status and Timeline

3.2.4 Consistent Identification (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software) – Does not apply to non-web software
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs) – Does not apply to non-web docs

Software:

Supports with Exceptions

Software:

  • Page Section label - no H1 or H2 found in the page


View Transferology Lab Accessibility Roadmap for Status and Timeline

3.3.3 Error Suggestion (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports with Exceptions


Software:

  • When a user logins with invalid password, screen reader does not read the error back to the user

View Transferology Lab Accessibility Roadmap Status and Timeline



3.3.4 Error Prevention (Legal, Financial, Data) (Level AA)

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software: Supports


Software: No known issue


 

Table 3: Conformance Criteria, Level AAA

Notes:

Criteria

Conformance Level

Remarks and Explanations

1.2.6 Sign Language (Prerecorded) (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

1.2.7 Extended Audio Description (Prerecorded) (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

1.2.8 Media Alternative (Prerecorded) (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

1.2.9 Audio-only (Live) (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

1.4.6 Contrast Enhanced  (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated


1.4.7 Low or No Background Audio (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

1.4.8 Visual Presentation (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

1.4.9 Images of Text (No Exception) Control (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

2.1.3 Keyboard (No Exception) (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

2.2.3 No Timing (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

2.2.4 Interruptions (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

2.2.5 Re-authenticating (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

2.3.2 Three Flashes (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

2.4.8 Location (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

2.4.9 Link Purpose (Link Only) (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

2.4.10 Section Headings (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated


3.1.3 Unusual Words (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

3.1.4 Abbreviations (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

3.1.5 Reading Level (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

3.1.6 Pronunciation (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

3.2.5 Change on Request (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

3.3.5 Help (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated

3.3.6 Error Prevention (All) (Level AAA)

Also applies to:

2017 Section 508 – Does not apply

Web: Not Evaluated

Software: Not Evaluated

Web: Not Evaluated

Software: Not Evaluated


Table 4: WCAG Conformance Requirements

Notes:

Criteria

Conformance Level

Remarks and Explanations

1. Conformance Level

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Reminder: WCAG level must be included in your answer

Software:(WCAG Level: )

2. Full pages

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Software:(WCAG Level: )

3. Complete processes

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • E207.3 (Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Software:(WCAG Level: )

4. Only Accessibility-Supported Ways of Using Technologies

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Software:(WCAG Level: )

5. Non-Interference

Also applies to:

2017 Section 508

  • 501 (Web)(Software)
  • 504.2 (Authoring Tool)
  • 602.3 (Support Docs)

Software:

Software:(WCAG Level: )

2017 Section 508 Report

Notes:

Chapter 3: Functional Performance Criteria

Notes:

Criteria

Conformance Level

Remarks and Explanations

302.1 Without Vision



302.2 With Limited Vision



302.3 Without Perception of Color



302.4 Without Hearing



302.5 With Limited Hearing



302.6 Without Speech



302.7 With Limited Manipulation



302.8 With Limited Reach and Strength



302.9 With Limited Language, Cognitive, and Learning Abilities



Chapter 4: Hardware

Notes:

Criteria

Conformance Level

Remarks and Explanations

402 Closed Functionality



402.1 General

  Not Applicable

 N/A

402.2 Speech-Output Enabled

  Not Applicable

 N/A

402.2.1 Information Displayed On-Screen

  Not Applicable

 N/A

402.2.2 Transactional Outputs

  Not Applicable

 N/A

402.2.3 Speech Delivery Type and Coordination

  Not Applicable

 N/A

402.2.4 User Control

  Not Applicable

 N/A

402.2.5 Braille Instructions

  Not Applicable

 N/A

402.3 Volume

  Not Applicable

 N/A

402.3.1 Private Listening

  Not Applicable

 N/A

402.3.2 Non-private Listening

  Not Applicable

 N/A

402.4 Characters on Display Screens

  Not Applicable

 N/A

402.5 Characters on Variable Message Signs

  Not Applicable

 N/A

403 Biometrics



403.1 General

  Not Applicable

 N/A

404 Preservation of Information Provided for Accessibility


 N/A

404.1 General

 Not Applicable

 N/A

405 Privacy



405.1 General

 Not Applicable

 N/A

406 Standard Connections



406.1 General

 Not Applicable

 N/A

407 Operable Parts



407.2 Contrast

 Not Applicable

 N/A

407.3 Input Controls

 Not Applicable

 N/A

407.3.1 Tactilely Discernible

 Not Applicable

 N/A

407.3.2 Alphabetic Keys

 Not Applicable

 N/A

407.3.3 Numeric Keys

 Not Applicable

 N/A

407.4 Key Repeat

 Not Applicable

 N/A

407.5 Timed Response

 Not Applicable

 N/A

407.6 Operation

 Not Applicable

 N/A

407.7 Tickets, Fare Cards, and Keycards

 Not Applicable

 N/A

407.8 Reach Height and Depth



407.8.1 Vertical Reference Plane

 Not Applicable

 N/A

407.8.1.1 Vertical Plane for Side Reach

 Not Applicable

 N/A

407.8.1.2 Vertical Plane for Forward Reach

 Not Applicable

 N/A

407.8.2 Side Reach

 Not Applicable

 N/A

407.8.2.1 Unobstructed Side Reach

 Not Applicable

 N/A

407.8.2.2 Obstructed Side Reach

 Not Applicable

 N/A

407.8.3 Forward Reach

 Not Applicable

 N/A

407.8.3.1 Unobstructed Forward Reach

 Not Applicable

 N/A

407.8.3.2 Obstructed Forward Reach

 Not Applicable

 N/A

407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach

 Not Applicable

 N/A

407.8.3.2.2 Knee and Toe Space under ICT with Obstructed Forward Reach

 Not Applicable

 N/A

408 Display Screens



408.2 Visibility

 Not Applicable

 N/A

408.3 Flashing

 Not Applicable

 N/A

409 Status Indicators



409.1 General

 Not Applicable

 N/A

410 Color Coding



410.1 General

 Not Applicable

 N/A

411 Audible Signals



411.1 General

 Not Applicable

 N/A

412 ICT with Two-Way Voice Communication



412.2.1 Volume Gain for Wireline Telephones

 Not Applicable

 N/A

412.2.2 Volume Gain for Non-Wireline ICT

 Not Applicable

 N/A

412.3 Interference Reduction and Magnetic Coupling



412.3.1 Wireless Handsets

 Not Applicable

 N/A

412.3.2 Wireline Handsets

 Not Applicable

 N/A

412.4 Digital Encoding of Speech

 Not Applicable

 N/A

412.5 Real-Time Text Functionality



412.6 Caller ID

 Not Applicable

 N/A

412.7 Video Communication

 Not Applicable

 N/A

413 Closed Caption Processing Technologies



413.1.1 Decoding and Display of Closed Captions

 Not Applicable

 N/A

413.1.2 Pass-Through of Closed Caption Data

 Not Applicable

 N/A

414 Audio Description Processing Technologies



414.1.1 Digital Television Tuners

 Not Applicable

 N/A

414.1.2 Other ICT

 Not Applicable

 N/A

415 User Controls for Captions and Audio Descriptions



415.1.1 Caption Controls

 Not Applicable

 N/A

415.1.2 Audio Description Controls

 Not Applicable

 N/A

Chapter 5: Software

Notes:

Criteria

Conformance Level

Remarks and Explanations

501 Scope – Incorporation of WCAG 2.0 AA

See WCAG 2.0 section


502 Interoperability with Assistive Technology



502.2.1 User Control of Accessibility Features



502.2.2 No Disruption of Accessibility Features



502.3 Accessibility Services



502.3.1 Object Information



502.3.2 Modification of Object Information



502.3.3 Row, Column, and Headers



502.3.4 Values



502.3.5 Modification of Values



502.3.6 Label Relationships



502.3.7 Hierarchical Relationships



502.3.8 Text



502.3.9 Modification of Text



502.3.10 List of Actions



502.3.11 Actions on Objects



502.3.12 Focus Cursor



502.3.13 Modification of Focus Cursor



502.3.14 Event Notification



502.4 Platform Accessibility Features



503 Applications



503.2 User Preferences



503.3 Alternative User Interfaces



503.4 User Controls for Captions and Audio Description.



503.4.1 Caption Controls



503.4.2 Audio Description Controls



504 Authoring Tools



504.2 Content Creation or Editing

See WCAG 2.0 section


504.2.1 Preservation of Information Provided for Accessibility in Format Conversion



504.2.2 PDF Export



504.3 Prompts



504.4 Templates



Chapter 6: Support Documentation and Services

Notes:

Criteria

Conformance Level

Remarks and Explanations

601.1 Scope



602 Support Documentation



602.2 Accessibility and Compatibility Features



602.3 Electronic Support Documentation

See WCAG 2.0 section


602.4 Alternate Formats for Non-Electronic Support Documentation



603 Support Services



603.2 Information on Accessibility and Compatibility Features



603.3 Accommodation of Communication Needs




Legal Disclaimer (Company)

CollegeSource, Inc. is committed to making its website and suite of products accessible through constant review and redesign, as necessary, to ensure that they meet or exceed accessibility standards and guidelines. We appreciate your patience through this ongoing process.

CollegeSource, Inc. incurs no responsibility for third party customization or manipulation of an application that compromises the intended accessibility of a product.

Still have questions regarding accessibility features? Contact us.